Clear laboratory guidelines address laboratory techniques and quality control procedures. For example, the World Health Organization manual (WHO, 1999) outlines the basis for standardized techniques and practices, and the NAFA-ESHRE manual (Kvist and Björndahl, 2002) provides more detailed instructions for the techniques recommended by the WHO. These detailed procedures allow further standardization based on the techniques taught at ESHRE Basic Semen Analysis Courses within and outside the European Union (Punjabi and Spiessens, 1998; Vreeburg and Weber, 1998; Björndahl et al, 2002). Also, a number of practical suggestions on how to run training programs within a clinical laboratory setting have been made, and solutions have been implemented successfully (eg, Mortimer, 1994a,b; Franken et al, 2003).
We have to ask ourselves: What is it that so efficiently hinders the improvement of quality in the andrology laboratory? A major factor must be a lack of knowledge and understanding of what is requiredwithin the laboratory profession and among its customers (cf. Edwards, 2004; Figure 1). Two main directions of development are therefore crucial. Laboratory staff need to understand the reasons for and the practical aspects of the recommended techniques (eg, WHO, 1999). Clinicians (the end users) need to know what should be demanded from laboratory services in terms of quality. If both these developments are not achieved, the current low performance in many laboratories will make semen analysis an undervalued and out-of-date procedure (cf. McDonough, 1997; Figure 2).
|
|
A frequent objection against training and quality control activities in the andrology laboratory is that it takes too much time and therefore costs too much. However, what is the cost of using results obtained without proper techniques and quality control? In a competitive world, it is essential that the clinician understand enough laboratory science to be able to choose laboratory services that provide high-quality analyses. If there is a demand for quality and it is used as a benchmark, the laboratory profession will find it easier to justify further training of staff and investment in quality control. In this context, it is critical to remember that semen analysis is a diagnostic tool, and as such, the results are used to guide patient treatment. Poor technique will undoubtedly lead to the wrong diagnosis and inappropriate therapy.
The basis for standardized laboratory andrology is well described. For example, the ESHRE Basic Semen Analysis Course provides a good example of a standardized course that offers training in the basic techniques. However, no laboratory staff can be trained to satisfactory levels in a 4-day course. After an introductory course, further training is mandatory until the individual is fully trained. This can only be done with serious commitment. To support continued training "at home," the ESHRE external quality control (EQC) scheme is developing sets of training materialsimilar to that sent out for EQC assessments, but with target values obtained from reference laboratories in the EQC scheme. After a sufficient period of in-house training and practical work, the individual would be expected to be fully trained, and it is from this point that participation in proficiency testing is of real value to monitor assessing skills.
When proper training has been completed, IQC should be implemented as a tool to decrease inter- and intratechnician variability and to ensure that technical skills are maintained at a high standard. Finally, EQC should be introduced to monitor proficiency in relationship to other laboratories. Although considerable work is still to be done regarding standardization of EQC schemes (Cooper et al, 2002) and fine tuning of the WHO recommendations (Björndahl et al, 2003, in press), these relatively minor aspects are not adequate apologies for not complying with the recommendations that already exist (De Jonge and Barratt, 1999).
Conclusion![]()
There are no excuses for not improving the standards in laboratory
andrology: detailed descriptions of robust, reliable techniques and procedures
already exist. Although improvements can be made in the existing guidelines,
protocols, and quality control systems, these systems provide much better
tools than other, nonstandardized procedures ever can. Although each
laboratory performing semen analyses must take the responsibility to implement
proper techniques and training, the professional and scientific bodies (eg,
the American Society of Andrology, ASRM, and ESHRE) must collaborate to unite
on standardized education of laboratory staff and clinicians, as well as on
standards for EQC and proficiency testing. Our patients deserve a high-quality
professional service.
Acknowledgments
The authors are grateful to Professor Christopher J. De Jonge for his comments in formulating this opinion article.
Footnotes
* Andrology Lab Corner welcomes the submission of unsolicited
manuscripts, requested reviews, and articles in a debate format. Manuscripts
will be reviewed and edited by the Section Editor. All submissions should be
sent to the Journal of Andrology Editorial Office. Letters to
the editor in response to articles as well as suggested topics for future
issues are encouraged. ![]()
References
Björndahl L, Barratt CLR, Fraser L, Kvist U, Mortimer D. ESHRE
basic semen analysis courses 19951999: immediate beneficial effects of
standardized training. Hum Reprod. 2002; 17: 1299
-1305.
Björndahl L, Söderlund I, Kvist U. Evaluation of the
one-step eosinnigrosin staining technique for human sperm vitality assessment.
Hum Reprod. 2003; 18: 813
-816.
Björndahl L, Söderlund I, Johansson S, Mohammadieh M, Pourian MR, Kvist U. Why the WHO recommendations for eosin-nigrosin staining techniques for human sperm vitality assessment must change. J Androl. 2004. In press.
Brazil C, Swan SH, Drobnis EZ, Liu F, Wang C, Redmon JB, Overstreet
JW. Standardized methods for semen evaluation in a multicentre research study.
J Androl. 2004a; 25: 645
-656.
Brazil C, Swan SH, Tollner CR, Treece C, Drobnis EZ, Wang C, Redmon JB, Overstreet JW. Quality control of laboratory methods for semen analysis in a multicentre research study. J Androl. 2004b; 25: 645 -656.
Cooper TG, Björndahl L, Vreeburg J, Nieschlag E. Semen analysis and external quality control schemes for semen analysis need global standardization. Int J Androl. 2002; 25: 306 -311.[Medline]
De Jonge CJ, Barratt CLR. WHO manual... Who should care?
Hum Reprod. 1999; 14: 2431
-2433.
Edwards PN. "A Vast Machine": standards as social
technology. Science. 2004; 304: 827
-828.
Franken DR, Menkveld R, Kruger TF, Sekadde-Kigondu C, Lombard C. Monitoring technologist reading skills in a sperm morphology quality control program. Fertil Steril. 2003; 79(suppl 3): 1637 -1643.
Keel BA. How reliable are results from the semen analysis? Fertil Steril. 2004; 82: 41 -44.[Medline]
Kvist U, Björndahl L, eds. Manual on Basic Semen Analysis. ESHRE Monographs . Oxford, United Kingdom: Oxford University Press; 2002.
McDonough PG. Has traditional sperm analysis lost its clinical relevance. Fertil Steril. 1997; 67: 596 -587.
Mortimer D. Laboratory standards in routine clinical andrology. Reprod Med Rev. 1994a; 3: 97 -111.
Mortimer D. Practical Laboratory Andrology. Oxford, United Kingdom: Oxford University Press; 1994b .
Punjabi U, Spiessens C. Basic semen analysis courses: Experience in Belgium. In: Ombelet W, Bosmans E, Vandeput H, Vereecken A, Renier M, Hoomnas, eds. Modern ART in the 2000sAndrology in the Nineties. New York/London: Parthenon; 1998: 107 -113.
Vreeburg JTM, Weber RFA. Basic semen analysis courses: Experience in the Netherlands. In: Ombelet W, Bosmans E, Vandeput H, Vereecken A, Renier M, Hoomnas, eds. Modern ART in the 2000sAndrology in the Nineties. New York/London: Parthenon; 1998: 103 -106.
World Health Organization (WHO). WHO Laboratory Manual for the Examination of Human Semen and Sperm-Cervical Mucus Interaction. 3rd ed. Cambridge, United Kingdom: Cambridge University Press; 1999 .
This article has been cited by other articles:
![]() |
L. Bjorndahl and C. L. R. Barratt Semen Analysis: Setting Standards for the Measurement of Sperm Numbers J Androl, January 1, 2005; 26(1): 11 - 11. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |