Journal of Andrology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, R. O.
Right arrow Articles by Katz, D. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, R. O.
Right arrow Articles by Katz, D. F.

Journal of Andrology, Vol 14, Issue 5 385-394, Copyright © 1993 by The American Society of Andrology


REVIEW

Operational standards for CASA instruments

R. O. Davis and D. F. Katz
Department of Obstetrics and Gynecology, School of Medicine, University of California, Davis 95616.

Computer-aided sperm analysis (CASA) technology is 7 years old. Over 120 papers have been written that verify the technology or apply it in basic and clinical studies. Most of the technical problems with CASA, such as the dependence of velocity on video frame rate, inaccuracy of count and percent motility for low- and high-concentration specimens, parameter dependence on the number of frames analyzed, sensitivity of the subjective threshold setting, confusion over the presence of debris, and different implementations of algorithms across instruments, still persist. A critical review of the literature reveals that no standard practices are followed within or across instruments. Moreover, no standards have been embraced or recommended by professional societies. Despite its potential to provide objective measurements of specimen and individual sperm parameters, and to automate the laboratory semen analysis, the promise of CASA has not been fulfilled. Unless laboratory medicine defines instrument performance and laboratory standards and co-operates with industry to achieve these goals, CASA technology may remain a research curiosity. This outcome is especially worrisome in the context of increasing requirements for laboratory accuracy, precision, standardization, and accreditation under the Clinical Laboratory Improvement Act of 1988.


This article has been cited by other articles:


Home page
J AndrolHome page
A. Agarwal, R. K. Sharma, and D. R. Nelson
New Semen Quality Scores Developed by Principal Component Analysis of Semen Characteristics
J Androl, May 1, 2003; 24(3): 343 - 352.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by The American Society of Andrology.